TY12048E600P4 Specification
General Information
Our ESS is an off-grid system, helps you manage your power as a personal resource. It optimizes integration of solar、utility、generator-off grid and protects your home and mission critical business functions from power outages and intermittency.
Product Description
- Plug & Play/All-In-One Design Make the system performance best
- 19"Stardand Rack Design for all modules
- 12Kw Low Frequency Pure Sinewave Inverter & Charger Built-in
- 60-145Vdc PV range MPPT Built-in
- Long Cycle Life LiFePO4 Battery
- Lithium iron phosphate guarantees high safety, good stability and long working life with at least 3500 cycles at 80% DOD
- High reliability intelligent BMS
- Unique automatic calibration active balancing technology BMS system
Product Details
Basic Specification
Battery |
Description |
|
Normal specification |
||
1 |
Rated Voltage |
51.2V |
2 |
Rated Capacity |
600Ah |
3 |
Rated Energy |
30.72KWH |
4 |
Battery Configuration |
10.24KWH (16S2P) *3PCS |
5 |
Battery Cell |
3.2V100AH 96PCS |
Standard Charge |
||
1 |
Operation temperature range @charging |
0~45℃ |
2 |
Rated charge voltage |
55.2±0.4V |
3 |
Max charge voltage |
56.8±0.4V |
4 |
Overcharge protection |
58.4±0.4V |
5 |
Allowed MAX charge current (Total) |
330A withstand 30s (every pack 110A) |
6 |
Peak charge current (Total) |
360A withstand 5s (every pack 120A) |
7 |
Rated charge current (Total) |
300A (every pack 100A) |
8 |
Recommend charge current (Total) |
<300A |
Standard discharge |
||
1 |
Operation temperature range @discharging |
-20~60℃ |
2 |
Output Voltage Range |
40~56Vdc |
3 |
Recommend Working Range |
46~54Vdc |
4 |
Discharge Cut-off voltage |
40V |
5 |
Allowed MAX discharge current (Total) |
660A withstand 30s (every pack 220A) |
6 |
Peak discharge current (Total) |
720A withstand 5s (every pack 240A) |
7 |
Rated discharge current (Total) |
600A (every pack 200A) |
8 |
Recommend discharge current (Total) |
<600A |
Communication |
||
1 |
RS485 |
For LCD remote |
2 |
CAN |
PC control and monitor |
Inverter (built-in) |
Description |
|
Normal specification |
||
1 |
Rated Power |
12KW |
2 |
Output Waveform |
Pure Sine Wave/Same as input (Bypass Mode) |
3 |
Output Voltage |
240Vac(H-H)/120Vac(H-N) ±10% RMS |
4 |
Output Frequency |
50 or 60± 0.3Hz (Inverter mode by sw4 setting) |
5 |
Typical Transfer Time |
4-6ms typical,10ms (Max) |
6 |
THD |
< 3% (Rated voltage full R load) |
7 |
AC Input Range |
184-253Vac (UPS mode) or 140-270Vac (GEN mode) |
8 |
Customized AC Charger |
Battery type selector position 9, special design for LFP, make the battery cycle life Maximization |
9 |
MAX AC Charge Current |
100A |
10 |
Battery priority Function |
Setting by SW5 on position 1 (inverter mode valid), AC automatic come in when battery voltage low alarm at 48Vdc or 50Vdc |
11 |
AC Bypass without charging |
Battery type selector position 0 |
MPPT (built-in) |
Description |
|
Normal specification |
||
1 |
PV POWER |
3.5KW*4 |
2 |
PV Input Voltage |
60-145Vdc |
3 |
MPPT Charging Voltage |
56.0Vdc (Fast charging)/54Vdc (Float charging) |
4 |
MPPT Output Current |
60A*4 |
Model |
Configuration |
|||
TY12048E600P4 |
MPPT |
INVERTER |
BATTERY |
Energy |
240A(60A*4) |
12KW |
600AH (200AH*4) |
30.72kwh |
Mechanical Characteristics |
||||
TY12048E600P4 |
Dimension H*W*D |
Shipping H*W*D |
Weight (N.W.) |
Weight (G.W.) |
1360*560*960mm |
1540*700*1050mm |
440KG |
480KG |